ISSN   1004-0595

CN  62-1224/O4

Advanced Search
ZHU Yong-kui, CAI Zhen-bing, ZHANG Guang-an, PENG Jin-fang, SHEN Ming-xue, SHEN Huo-ming, ZHU Min-hao. Comparison on the Torsional Fretting Wear of Nitrogen Ion Implanted Pure Titanium and Ti6Al7Nb Alloys in Bovine Serum[J]. TRIBOLOGY, 2013, 33(2): 196-201.
Citation: ZHU Yong-kui, CAI Zhen-bing, ZHANG Guang-an, PENG Jin-fang, SHEN Ming-xue, SHEN Huo-ming, ZHU Min-hao. Comparison on the Torsional Fretting Wear of Nitrogen Ion Implanted Pure Titanium and Ti6Al7Nb Alloys in Bovine Serum[J]. TRIBOLOGY, 2013, 33(2): 196-201.

Comparison on the Torsional Fretting Wear of Nitrogen Ion Implanted Pure Titanium and Ti6Al7Nb Alloys in Bovine Serum

  • Pure titanium and Ti6Al7Nb alloys alloys were implanted by 50 keV N+ ions with different implanting dosage in high energy ion implantation and enhanced deposition system. Torsional fretting wear of un-treated and plasma implantation nitride titanium alloys flats against ZrO2 ball (with a diameter of 25.2 mm) were carried out under a simulated physiological condition. With analyses of the frictional kinetics behaviors, the X-ray diffraction, Raman spectroscopy, 3-D profiler,SEM morphologies, the damage characteristics of the surface modification layer and its substrate were discussed in detail.The results show that the plasma implantation nitride can improve its surface properties and the resistance of torsional fretting wear can be improved obviously.The wear mechanism of the pure titanium and Ti6Al7Nb were oxidation wear and delaminlation, the ploughing of the modification layers.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return